Quick answer

Choosing between AC, DC and mobile charging means matching equipment ratings to the vehicle: the EON220/32-1 is a 7 kW AC wallbox, DC systems offer 120–400 kW with CCS2 at 200–1000V, and the EON-MS-208/90-A mobile unit stores 208 kWh and delivers up to 90 kW.

Equipment selection

Choose the right charging format

AC, DC and mobile storage solve different planning problems. Compare the vehicle, charging window and site supply before comparing power alone.

01

Equipment selection

7 kW AC charger · EON220/32-1CCS2 DC fast charging system · EON120KW-400KW208 kWh mobile charging system · EON-MS-208/90-A

Equipment comparison

Decision summary

Three formats, different planning needs

FormatListed equipmentPlan around
AC charging7 kW · GB/T · EON220/32-1Vehicle AC capability and parking time
CCS2 DC120–400 kW · 200–1000 VSite supply, vehicle demand and output allocation
Mobile storage208 kWh nominal · up to 90 kW DCUsable energy, recharge time and safe movement

Power and capacity are different quantities. Actual charging performance depends on the vehicle, configuration and operating conditions.

Start with the charging task

List the vehicles and their charging interfaces, how long they stay parked and the power available. For mobile charging, add the locations and frequency of movement. These details narrow the equipment choice before a power rating does.

AC charging for longer parking windows

The EON220/32-1 is a 220 V, 7 kW AC charger with a GB/T connector. Match it to the vehicle inlet and onboard AC charging capability. For a location with longer dwell times, confirm the mounting, cable arrangement and electrical supply with the installation team.

DC charging: match power and allocation

The CCS2 family offers 120, 160, 200, 240, 320, 360 and 400 kW options with a 200–1000 V output range. Two connectors do not by themselves establish simultaneous full-power charging. Request the output allocation for the selected configuration and check it against vehicle demand.

Mobile storage: plan charging and recharge

The EON-MS-208/90-A has 208 kWh nominal storage, single-gun DC output up to 90 kW and 250 A, and AC recharge up to 60 kW. Plan the charging task together with the time and supply needed to replenish the battery. Actual energy delivered to vehicles depends on operating conditions.

Keep power and energy separate

Power describes the rate of energy transfer; storage capacity describes an amount of energy. Evaluate the vehicle charging limit, available site supply and charging window alongside both values. A larger cabinet rating alone cannot guarantee a shorter session.

Prepare the equipment discussion

Send the project country, vehicle list, charging windows and known supply conditions. Include the intended connector, backend and payment method where known. We can then discuss a model-specific configuration and identify the documents still needed.

Continue with a related guide

CCS2 and GB/TPlan the charging siteConnect equipment and operations

Frequently asked questions

What power does the EON220/32-1 AC charger provide?

The EON220/32-1 is a 7 kW AC charger rated at 220 V with a GB/T connector. That rating describes the equipment's output, so actual vehicle charging speed depends on the vehicle's onboard charger acceptance.

What DC fast charging power options are available?

DC fast charging systems are offered with rated power options of 120, 160, 200, 240, 320, 360 and 400 kW. The rating is the equipment's rated power, and the vehicle's own limits determine the actual charging rate achieved.

Which connector and voltage range do the DC systems use?

The DC fast charging systems use a CCS2 connector with an output voltage range of 200–1000V. Buyers should confirm that their vehicles' battery voltage falls within this range before specifying a system.

How much energy does the mobile charging system store?

The EON-MS-208/90-A mobile charging system has a nominal energy of 208 kWh. This stored capacity supports charging away from fixed grid connections, subject to the system's charging configuration.

What charging power does the mobile storage unit deliver?

The EON-MS-208/90-A is a single-gun mobile energy-storage DC charging pile with a maximum charging power of 90 kW and maximum current of 250 A. These are the unit's maximum external vehicle charging figures.

How is the mobile charging system's battery recharged?

The energy-storage battery pack is recharged via AC power, with a maximum AC recharging power of 60 kW. Recharge time therefore depends on the available AC supply and the pack's state of charge.

Why distinguish equipment ratings from actual vehicle charging performance?

Equipment ratings state what the charger can deliver, while actual vehicle charging performance is limited by the vehicle's onboard charger and battery. For example, a 7 kW AC charger only delivers 7 kW if the vehicle accepts that rate.

What should buyers check before choosing AC, DC or mobile charging?

Buyers should check the vehicle's connector type, accepted AC and DC charging power, and battery voltage range against the equipment specifications. The DC systems use CCS2 at 200–1000V, while the AC wallbox uses a GB/T connector at 220 V.

Talk to us about your project

Tell us which product you are considering and where it will be used.

Lingxiu Yungu, No. 699 Yunli Road, Jiangling Sub-district, Wujiang District, Suzhou, China

We use your contact details to respond to this enquiry.

Your enquiry will be sent to our team.

Project enquiry ↗

Website information assistant

Ask about information on this site. Prices, certifications and project feasibility require confirmation from the team.

Privacy

Do not include personal or confidential information. Your question is processed by an AI service to select website information. This conversation is not saved in the site history. Enquiries to the team are sent separately.

Open original